Review




Structured Review

DiaSorin Molecular simplexa flu a/b and rsv direct assay
Simplexa Flu A/B And Rsv Direct Assay, supplied by DiaSorin Molecular, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simplexa+flu/simplexa+flu+a+b+and+rsv+direct+assay/pmc09860520__jamanetwopen___e2250634___s001-45-13-16
Average 90 stars, based on 1 article reviews
simplexa flu a/b and rsv direct assay - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

Virus:

Article Title: Portable molecular diagnostic instruments in microbiology: current status.
Article Snippet: Manufacturers of the assays reviewed: cobas Liat Influenza A&B assay, cobas Liat Influenza A/B&RSV assay, cobas Cdiff assay and cobas Strep A test (Roche Molecular Diagnostics, Pleasanton, CA, USA); Xpert Xpress Flu/RSV assay (Cepheid, Sunnyvale, CA, USA); FTD Respiratory pathogens 21 panel (FastTrack Diagnostics, Siema, Malta); Alere i Influenza A&B assay or ID Now (Abbott Molecular, Des Plaines, IL, USA); Influenza A/B R-GENE and BioFire Film Array respiratory panel (bioM erieux, Marcy-l’ Etoile, France); xTAG Respiratory Pathogen Panel and Aries Flu A/B&RSV assay (Luminex, Austin, TX, USA), GenMark Dx respiratory viral panel and ePlex-RPP (GenMark Diagnostics, Carlsbad, CA, USA), Simplexa Flu A&B/RSV assay (DiaSorin Molecular, Cypress, CA, USA), Panther Fusion Flu A/B&RSV assay and Prodesse ProFluþ assay (Hologic, Marlborough, MA, USA), R-Dia Flu Influenza A and B assay (Diagenode, Li ege, Belgium) and Quick Vue RADT (Quidel, San Diego, CA, USA). require manual calibration or service and provides an interpreted result in less than 90 minutes.

Article Title: Retrospective observational study of the influence of the COVID-19 outbreak on infants’ hospitalisation for acute bronchiolitis
Article Snippet: The clinical data collected at the time of the bronchiolitis episode included date, age, weight, results of the PCR in nasopharyngeal swabs or aspirates for virus identification (Allplex Respiratory Panel Assays (Seegene), and/or Simplexa Flu A/B & RSV Direct Gen II Kit (Diasorin Molecular)), and medical evolution with duration of the hospitalisation, hopitalisation in ICU, respiratory support (oxygen therapy, high-flow nasal cannula oxygen therapy, non-invasive ventilation, invasive ventilation, and extracorporeal membrane oxygenation, and nutritional support.

Article Title: Influenza infection is not associated with phenotypical frailty in older patients, a prospective cohort study.
Article Snippet: The primary predictor was influenza infection as diagnosed by PCR (Simplexa Flu A/B and RSV Direct; DiaSorin Molecular).

Article Title: Comparison of the Panther Fusion respiratory panels to routine methods for detection of viruses in upper and lower respiratory tract specimens.
Article Snippet: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record.. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article.. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Article Title: Influenza A subtype H3N2 is associated with an increased risk of hospital dissemination - an observational study over six influenza seasons.
Article Snippet: Influenza A and B virus was detected with RT-PCR (Simplexa Flu A/B and RSV direct kit (DiaSorin Molecular LLC, CA, USA) performed on nasopharyngeal swab samples [25].

Article Title: Clinical Impact of Rapid Point-of-Care PCR Influenza Testing in an Urgent Care Setting: a Single-Center Study
Article Snippet: Negative specimens were further evaluated by batched reflex confirmatory testing by PCR using the Simplexa Flu A/B RSV assay (Diasorin Molecular LLC, Cypress, CA) performed at our centralized clinical laboratory.

Article Title: Summarizing Study Characteristics and Diagnostic Performance of Commercially Available Tests for Respiratory Syncytial Virus: A Scoping Literature Review in the COVID-19 Era
Article Snippet: Simplexa Flu A/B & RSV , Diasorin Molecular , Molecular , 60 , Nasopharyngeal swab , Not specified , 73.3 (44.8–91.0) to 87.0 (74.5–94.2) , 99.4 (96.3–99.9) to 100 (98.9–100) , 3 , ( , , ) .

Article Title: Comparative Evaluation of cobas Influenza A/B & RSV and Simplexa Flu A/B & RSV for Rapid Detection of Influenza and Respiratory Syncytial Viruses
Article Snippet: In this study, we compared the cobas Influenza A/B & RSV (cobas Liat; Roche Diagnostics, Indianapolis, IN) with the Simplexa Flu A/B & RSV (Simplexa; Diasorin Molecular, Cypress, CA), and evaluated their performance against the routine RT-PCR method.

Reverse Transcription Polymerase Chain Reaction:

Article Title: Portable molecular diagnostic instruments in microbiology: current status.
Article Snippet: Manufacturers of the assays reviewed: cobas Liat Influenza A&B assay, cobas Liat Influenza A/B&RSV assay, cobas Cdiff assay and cobas Strep A test (Roche Molecular Diagnostics, Pleasanton, CA, USA); Xpert Xpress Flu/RSV assay (Cepheid, Sunnyvale, CA, USA); FTD Respiratory pathogens 21 panel (FastTrack Diagnostics, Siema, Malta); Alere i Influenza A&B assay or ID Now (Abbott Molecular, Des Plaines, IL, USA); Influenza A/B R-GENE and BioFire Film Array respiratory panel (bioM erieux, Marcy-l’ Etoile, France); xTAG Respiratory Pathogen Panel and Aries Flu A/B&RSV assay (Luminex, Austin, TX, USA), GenMark Dx respiratory viral panel and ePlex-RPP (GenMark Diagnostics, Carlsbad, CA, USA), Simplexa Flu A&B/RSV assay (DiaSorin Molecular, Cypress, CA, USA), Panther Fusion Flu A/B&RSV assay and Prodesse ProFluþ assay (Hologic, Marlborough, MA, USA), R-Dia Flu Influenza A and B assay (Diagenode, Li ege, Belgium) and Quick Vue RADT (Quidel, San Diego, CA, USA). require manual calibration or service and provides an interpreted result in less than 90 minutes.

Article Title: Retrospective observational study of the influence of the COVID-19 outbreak on infants’ hospitalisation for acute bronchiolitis
Article Snippet: The clinical data collected at the time of the bronchiolitis episode included date, age, weight, results of the PCR in nasopharyngeal swabs or aspirates for virus identification (Allplex Respiratory Panel Assays (Seegene), and/or Simplexa Flu A/B & RSV Direct Gen II Kit (Diasorin Molecular)), and medical evolution with duration of the hospitalisation, hopitalisation in ICU, respiratory support (oxygen therapy, high-flow nasal cannula oxygen therapy, non-invasive ventilation, invasive ventilation, and extracorporeal membrane oxygenation, and nutritional support.

Article Title: Influenza infection is not associated with phenotypical frailty in older patients, a prospective cohort study.
Article Snippet: The primary predictor was influenza infection as diagnosed by PCR (Simplexa Flu A/B and RSV Direct; DiaSorin Molecular).

Article Title: Comparison of the Panther Fusion respiratory panels to routine methods for detection of viruses in upper and lower respiratory tract specimens.
Article Snippet: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record.. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article.. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Article Title: Influenza A subtype H3N2 is associated with an increased risk of hospital dissemination - an observational study over six influenza seasons.
Article Snippet: Influenza A and B virus was detected with RT-PCR (Simplexa Flu A/B and RSV direct kit (DiaSorin Molecular LLC, CA, USA) performed on nasopharyngeal swab samples [25].

Article Title: Clinical Impact of Rapid Point-of-Care PCR Influenza Testing in an Urgent Care Setting: a Single-Center Study
Article Snippet: Negative specimens were further evaluated by batched reflex confirmatory testing by PCR using the Simplexa Flu A/B RSV assay (Diasorin Molecular LLC, Cypress, CA) performed at our centralized clinical laboratory.

Article Title: Summarizing Study Characteristics and Diagnostic Performance of Commercially Available Tests for Respiratory Syncytial Virus: A Scoping Literature Review in the COVID-19 Era
Article Snippet: Simplexa Flu A/B & RSV , Diasorin Molecular , Molecular , 60 , Nasopharyngeal swab , Not specified , 73.3 (44.8–91.0) to 87.0 (74.5–94.2) , 99.4 (96.3–99.9) to 100 (98.9–100) , 3 , ( , , ) .

Article Title: Comparative Evaluation of cobas Influenza A/B & RSV and Simplexa Flu A/B & RSV for Rapid Detection of Influenza and Respiratory Syncytial Viruses
Article Snippet: In this study, we compared the cobas Influenza A/B & RSV (cobas Liat; Roche Diagnostics, Indianapolis, IN) with the Simplexa Flu A/B & RSV (Simplexa; Diasorin Molecular, Cypress, CA), and evaluated their performance against the routine RT-PCR method.

Infection:

Article Title: Portable molecular diagnostic instruments in microbiology: current status.
Article Snippet: Manufacturers of the assays reviewed: cobas Liat Influenza A&B assay, cobas Liat Influenza A/B&RSV assay, cobas Cdiff assay and cobas Strep A test (Roche Molecular Diagnostics, Pleasanton, CA, USA); Xpert Xpress Flu/RSV assay (Cepheid, Sunnyvale, CA, USA); FTD Respiratory pathogens 21 panel (FastTrack Diagnostics, Siema, Malta); Alere i Influenza A&B assay or ID Now (Abbott Molecular, Des Plaines, IL, USA); Influenza A/B R-GENE and BioFire Film Array respiratory panel (bioM erieux, Marcy-l’ Etoile, France); xTAG Respiratory Pathogen Panel and Aries Flu A/B&RSV assay (Luminex, Austin, TX, USA), GenMark Dx respiratory viral panel and ePlex-RPP (GenMark Diagnostics, Carlsbad, CA, USA), Simplexa Flu A&B/RSV assay (DiaSorin Molecular, Cypress, CA, USA), Panther Fusion Flu A/B&RSV assay and Prodesse ProFluþ assay (Hologic, Marlborough, MA, USA), R-Dia Flu Influenza A and B assay (Diagenode, Li ege, Belgium) and Quick Vue RADT (Quidel, San Diego, CA, USA). require manual calibration or service and provides an interpreted result in less than 90 minutes.

Article Title: Retrospective observational study of the influence of the COVID-19 outbreak on infants’ hospitalisation for acute bronchiolitis
Article Snippet: The clinical data collected at the time of the bronchiolitis episode included date, age, weight, results of the PCR in nasopharyngeal swabs or aspirates for virus identification (Allplex Respiratory Panel Assays (Seegene), and/or Simplexa Flu A/B & RSV Direct Gen II Kit (Diasorin Molecular)), and medical evolution with duration of the hospitalisation, hopitalisation in ICU, respiratory support (oxygen therapy, high-flow nasal cannula oxygen therapy, non-invasive ventilation, invasive ventilation, and extracorporeal membrane oxygenation, and nutritional support.

Article Title: Influenza infection is not associated with phenotypical frailty in older patients, a prospective cohort study.
Article Snippet: The primary predictor was influenza infection as diagnosed by PCR (Simplexa Flu A/B and RSV Direct; DiaSorin Molecular).

Article Title: Comparison of the Panther Fusion respiratory panels to routine methods for detection of viruses in upper and lower respiratory tract specimens.
Article Snippet: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record.. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article.. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Article Title: Influenza A subtype H3N2 is associated with an increased risk of hospital dissemination - an observational study over six influenza seasons.
Article Snippet: Influenza A and B virus was detected with RT-PCR (Simplexa Flu A/B and RSV direct kit (DiaSorin Molecular LLC, CA, USA) performed on nasopharyngeal swab samples [25].

Article Title: Clinical Impact of Rapid Point-of-Care PCR Influenza Testing in an Urgent Care Setting: a Single-Center Study
Article Snippet: Negative specimens were further evaluated by batched reflex confirmatory testing by PCR using the Simplexa Flu A/B RSV assay (Diasorin Molecular LLC, Cypress, CA) performed at our centralized clinical laboratory.

Article Title: Summarizing Study Characteristics and Diagnostic Performance of Commercially Available Tests for Respiratory Syncytial Virus: A Scoping Literature Review in the COVID-19 Era
Article Snippet: Simplexa Flu A/B & RSV , Diasorin Molecular , Molecular , 60 , Nasopharyngeal swab , Not specified , 73.3 (44.8–91.0) to 87.0 (74.5–94.2) , 99.4 (96.3–99.9) to 100 (98.9–100) , 3 , ( , , ) .

Article Title: Comparative Evaluation of cobas Influenza A/B & RSV and Simplexa Flu A/B & RSV for Rapid Detection of Influenza and Respiratory Syncytial Viruses
Article Snippet: In this study, we compared the cobas Influenza A/B & RSV (cobas Liat; Roche Diagnostics, Indianapolis, IN) with the Simplexa Flu A/B & RSV (Simplexa; Diasorin Molecular, Cypress, CA), and evaluated their performance against the routine RT-PCR method.

Polymerase Chain Reaction:

Article Title: Portable molecular diagnostic instruments in microbiology: current status.
Article Snippet: Manufacturers of the assays reviewed: cobas Liat Influenza A&B assay, cobas Liat Influenza A/B&RSV assay, cobas Cdiff assay and cobas Strep A test (Roche Molecular Diagnostics, Pleasanton, CA, USA); Xpert Xpress Flu/RSV assay (Cepheid, Sunnyvale, CA, USA); FTD Respiratory pathogens 21 panel (FastTrack Diagnostics, Siema, Malta); Alere i Influenza A&B assay or ID Now (Abbott Molecular, Des Plaines, IL, USA); Influenza A/B R-GENE and BioFire Film Array respiratory panel (bioM erieux, Marcy-l’ Etoile, France); xTAG Respiratory Pathogen Panel and Aries Flu A/B&RSV assay (Luminex, Austin, TX, USA), GenMark Dx respiratory viral panel and ePlex-RPP (GenMark Diagnostics, Carlsbad, CA, USA), Simplexa Flu A&B/RSV assay (DiaSorin Molecular, Cypress, CA, USA), Panther Fusion Flu A/B&RSV assay and Prodesse ProFluþ assay (Hologic, Marlborough, MA, USA), R-Dia Flu Influenza A and B assay (Diagenode, Li ege, Belgium) and Quick Vue RADT (Quidel, San Diego, CA, USA). require manual calibration or service and provides an interpreted result in less than 90 minutes.

Article Title: Retrospective observational study of the influence of the COVID-19 outbreak on infants’ hospitalisation for acute bronchiolitis
Article Snippet: The clinical data collected at the time of the bronchiolitis episode included date, age, weight, results of the PCR in nasopharyngeal swabs or aspirates for virus identification (Allplex Respiratory Panel Assays (Seegene), and/or Simplexa Flu A/B & RSV Direct Gen II Kit (Diasorin Molecular)), and medical evolution with duration of the hospitalisation, hopitalisation in ICU, respiratory support (oxygen therapy, high-flow nasal cannula oxygen therapy, non-invasive ventilation, invasive ventilation, and extracorporeal membrane oxygenation, and nutritional support.

Article Title: Influenza infection is not associated with phenotypical frailty in older patients, a prospective cohort study.
Article Snippet: The primary predictor was influenza infection as diagnosed by PCR (Simplexa Flu A/B and RSV Direct; DiaSorin Molecular).

Article Title: Comparison of the Panther Fusion respiratory panels to routine methods for detection of viruses in upper and lower respiratory tract specimens.
Article Snippet: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record.. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article.. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Article Title: Influenza A subtype H3N2 is associated with an increased risk of hospital dissemination - an observational study over six influenza seasons.
Article Snippet: Influenza A and B virus was detected with RT-PCR (Simplexa Flu A/B and RSV direct kit (DiaSorin Molecular LLC, CA, USA) performed on nasopharyngeal swab samples [25].

Article Title: Clinical Impact of Rapid Point-of-Care PCR Influenza Testing in an Urgent Care Setting: a Single-Center Study
Article Snippet: Negative specimens were further evaluated by batched reflex confirmatory testing by PCR using the Simplexa Flu A/B RSV assay (Diasorin Molecular LLC, Cypress, CA) performed at our centralized clinical laboratory.

Article Title: Summarizing Study Characteristics and Diagnostic Performance of Commercially Available Tests for Respiratory Syncytial Virus: A Scoping Literature Review in the COVID-19 Era
Article Snippet: Simplexa Flu A/B & RSV , Diasorin Molecular , Molecular , 60 , Nasopharyngeal swab , Not specified , 73.3 (44.8–91.0) to 87.0 (74.5–94.2) , 99.4 (96.3–99.9) to 100 (98.9–100) , 3 , ( , , ) .

Article Title: Comparative Evaluation of cobas Influenza A/B & RSV and Simplexa Flu A/B & RSV for Rapid Detection of Influenza and Respiratory Syncytial Viruses
Article Snippet: In this study, we compared the cobas Influenza A/B & RSV (cobas Liat; Roche Diagnostics, Indianapolis, IN) with the Simplexa Flu A/B & RSV (Simplexa; Diasorin Molecular, Cypress, CA), and evaluated their performance against the routine RT-PCR method.

Surround Optical-fiber Immunoassay:

Article Title: Portable molecular diagnostic instruments in microbiology: current status.
Article Snippet: Manufacturers of the assays reviewed: cobas Liat Influenza A&B assay, cobas Liat Influenza A/B&RSV assay, cobas Cdiff assay and cobas Strep A test (Roche Molecular Diagnostics, Pleasanton, CA, USA); Xpert Xpress Flu/RSV assay (Cepheid, Sunnyvale, CA, USA); FTD Respiratory pathogens 21 panel (FastTrack Diagnostics, Siema, Malta); Alere i Influenza A&B assay or ID Now (Abbott Molecular, Des Plaines, IL, USA); Influenza A/B R-GENE and BioFire Film Array respiratory panel (bioM erieux, Marcy-l’ Etoile, France); xTAG Respiratory Pathogen Panel and Aries Flu A/B&RSV assay (Luminex, Austin, TX, USA), GenMark Dx respiratory viral panel and ePlex-RPP (GenMark Diagnostics, Carlsbad, CA, USA), Simplexa Flu A&B/RSV assay (DiaSorin Molecular, Cypress, CA, USA), Panther Fusion Flu A/B&RSV assay and Prodesse ProFluþ assay (Hologic, Marlborough, MA, USA), R-Dia Flu Influenza A and B assay (Diagenode, Li ege, Belgium) and Quick Vue RADT (Quidel, San Diego, CA, USA). require manual calibration or service and provides an interpreted result in less than 90 minutes.

Article Title: Retrospective observational study of the influence of the COVID-19 outbreak on infants’ hospitalisation for acute bronchiolitis
Article Snippet: The clinical data collected at the time of the bronchiolitis episode included date, age, weight, results of the PCR in nasopharyngeal swabs or aspirates for virus identification (Allplex Respiratory Panel Assays (Seegene), and/or Simplexa Flu A/B & RSV Direct Gen II Kit (Diasorin Molecular)), and medical evolution with duration of the hospitalisation, hopitalisation in ICU, respiratory support (oxygen therapy, high-flow nasal cannula oxygen therapy, non-invasive ventilation, invasive ventilation, and extracorporeal membrane oxygenation, and nutritional support.

Article Title: Influenza infection is not associated with phenotypical frailty in older patients, a prospective cohort study.
Article Snippet: The primary predictor was influenza infection as diagnosed by PCR (Simplexa Flu A/B and RSV Direct; DiaSorin Molecular).

Article Title: Comparison of the Panther Fusion respiratory panels to routine methods for detection of viruses in upper and lower respiratory tract specimens.
Article Snippet: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record.. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article.. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Article Title: Influenza A subtype H3N2 is associated with an increased risk of hospital dissemination - an observational study over six influenza seasons.
Article Snippet: Influenza A and B virus was detected with RT-PCR (Simplexa Flu A/B and RSV direct kit (DiaSorin Molecular LLC, CA, USA) performed on nasopharyngeal swab samples [25].

Article Title: Clinical Impact of Rapid Point-of-Care PCR Influenza Testing in an Urgent Care Setting: a Single-Center Study
Article Snippet: Negative specimens were further evaluated by batched reflex confirmatory testing by PCR using the Simplexa Flu A/B RSV assay (Diasorin Molecular LLC, Cypress, CA) performed at our centralized clinical laboratory.

Article Title: Summarizing Study Characteristics and Diagnostic Performance of Commercially Available Tests for Respiratory Syncytial Virus: A Scoping Literature Review in the COVID-19 Era
Article Snippet: Simplexa Flu A/B & RSV , Diasorin Molecular , Molecular , 60 , Nasopharyngeal swab , Not specified , 73.3 (44.8–91.0) to 87.0 (74.5–94.2) , 99.4 (96.3–99.9) to 100 (98.9–100) , 3 , ( , , ) .

Article Title: Comparative Evaluation of cobas Influenza A/B & RSV and Simplexa Flu A/B & RSV for Rapid Detection of Influenza and Respiratory Syncytial Viruses
Article Snippet: In this study, we compared the cobas Influenza A/B & RSV (cobas Liat; Roche Diagnostics, Indianapolis, IN) with the Simplexa Flu A/B & RSV (Simplexa; Diasorin Molecular, Cypress, CA), and evaluated their performance against the routine RT-PCR method.

Luminex:

Article Title: Portable molecular diagnostic instruments in microbiology: current status.
Article Snippet: Manufacturers of the assays reviewed: cobas Liat Influenza A&B assay, cobas Liat Influenza A/B&RSV assay, cobas Cdiff assay and cobas Strep A test (Roche Molecular Diagnostics, Pleasanton, CA, USA); Xpert Xpress Flu/RSV assay (Cepheid, Sunnyvale, CA, USA); FTD Respiratory pathogens 21 panel (FastTrack Diagnostics, Siema, Malta); Alere i Influenza A&B assay or ID Now (Abbott Molecular, Des Plaines, IL, USA); Influenza A/B R-GENE and BioFire Film Array respiratory panel (bioM erieux, Marcy-l’ Etoile, France); xTAG Respiratory Pathogen Panel and Aries Flu A/B&RSV assay (Luminex, Austin, TX, USA), GenMark Dx respiratory viral panel and ePlex-RPP (GenMark Diagnostics, Carlsbad, CA, USA), Simplexa Flu A&B/RSV assay (DiaSorin Molecular, Cypress, CA, USA), Panther Fusion Flu A/B&RSV assay and Prodesse ProFluþ assay (Hologic, Marlborough, MA, USA), R-Dia Flu Influenza A and B assay (Diagenode, Li ege, Belgium) and Quick Vue RADT (Quidel, San Diego, CA, USA). require manual calibration or service and provides an interpreted result in less than 90 minutes.

Article Title: Retrospective observational study of the influence of the COVID-19 outbreak on infants’ hospitalisation for acute bronchiolitis
Article Snippet: The clinical data collected at the time of the bronchiolitis episode included date, age, weight, results of the PCR in nasopharyngeal swabs or aspirates for virus identification (Allplex Respiratory Panel Assays (Seegene), and/or Simplexa Flu A/B & RSV Direct Gen II Kit (Diasorin Molecular)), and medical evolution with duration of the hospitalisation, hopitalisation in ICU, respiratory support (oxygen therapy, high-flow nasal cannula oxygen therapy, non-invasive ventilation, invasive ventilation, and extracorporeal membrane oxygenation, and nutritional support.

Article Title: Influenza infection is not associated with phenotypical frailty in older patients, a prospective cohort study.
Article Snippet: The primary predictor was influenza infection as diagnosed by PCR (Simplexa Flu A/B and RSV Direct; DiaSorin Molecular).

Article Title: Comparison of the Panther Fusion respiratory panels to routine methods for detection of viruses in upper and lower respiratory tract specimens.
Article Snippet: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record.. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article.. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Article Title: Influenza A subtype H3N2 is associated with an increased risk of hospital dissemination - an observational study over six influenza seasons.
Article Snippet: Influenza A and B virus was detected with RT-PCR (Simplexa Flu A/B and RSV direct kit (DiaSorin Molecular LLC, CA, USA) performed on nasopharyngeal swab samples [25].

Article Title: Clinical Impact of Rapid Point-of-Care PCR Influenza Testing in an Urgent Care Setting: a Single-Center Study
Article Snippet: Negative specimens were further evaluated by batched reflex confirmatory testing by PCR using the Simplexa Flu A/B RSV assay (Diasorin Molecular LLC, Cypress, CA) performed at our centralized clinical laboratory.

Article Title: Summarizing Study Characteristics and Diagnostic Performance of Commercially Available Tests for Respiratory Syncytial Virus: A Scoping Literature Review in the COVID-19 Era
Article Snippet: Simplexa Flu A/B & RSV , Diasorin Molecular , Molecular , 60 , Nasopharyngeal swab , Not specified , 73.3 (44.8–91.0) to 87.0 (74.5–94.2) , 99.4 (96.3–99.9) to 100 (98.9–100) , 3 , ( , , ) .

Article Title: Comparative Evaluation of cobas Influenza A/B & RSV and Simplexa Flu A/B & RSV for Rapid Detection of Influenza and Respiratory Syncytial Viruses
Article Snippet: In this study, we compared the cobas Influenza A/B & RSV (cobas Liat; Roche Diagnostics, Indianapolis, IN) with the Simplexa Flu A/B & RSV (Simplexa; Diasorin Molecular, Cypress, CA), and evaluated their performance against the routine RT-PCR method.

Membrane:

Article Title: Portable molecular diagnostic instruments in microbiology: current status.
Article Snippet: Manufacturers of the assays reviewed: cobas Liat Influenza A&B assay, cobas Liat Influenza A/B&RSV assay, cobas Cdiff assay and cobas Strep A test (Roche Molecular Diagnostics, Pleasanton, CA, USA); Xpert Xpress Flu/RSV assay (Cepheid, Sunnyvale, CA, USA); FTD Respiratory pathogens 21 panel (FastTrack Diagnostics, Siema, Malta); Alere i Influenza A&B assay or ID Now (Abbott Molecular, Des Plaines, IL, USA); Influenza A/B R-GENE and BioFire Film Array respiratory panel (bioM erieux, Marcy-l’ Etoile, France); xTAG Respiratory Pathogen Panel and Aries Flu A/B&RSV assay (Luminex, Austin, TX, USA), GenMark Dx respiratory viral panel and ePlex-RPP (GenMark Diagnostics, Carlsbad, CA, USA), Simplexa Flu A&B/RSV assay (DiaSorin Molecular, Cypress, CA, USA), Panther Fusion Flu A/B&RSV assay and Prodesse ProFluþ assay (Hologic, Marlborough, MA, USA), R-Dia Flu Influenza A and B assay (Diagenode, Li ege, Belgium) and Quick Vue RADT (Quidel, San Diego, CA, USA). require manual calibration or service and provides an interpreted result in less than 90 minutes.

Article Title: Retrospective observational study of the influence of the COVID-19 outbreak on infants’ hospitalisation for acute bronchiolitis
Article Snippet: The clinical data collected at the time of the bronchiolitis episode included date, age, weight, results of the PCR in nasopharyngeal swabs or aspirates for virus identification (Allplex Respiratory Panel Assays (Seegene), and/or Simplexa Flu A/B & RSV Direct Gen II Kit (Diasorin Molecular)), and medical evolution with duration of the hospitalisation, hopitalisation in ICU, respiratory support (oxygen therapy, high-flow nasal cannula oxygen therapy, non-invasive ventilation, invasive ventilation, and extracorporeal membrane oxygenation, and nutritional support.

Article Title: Influenza infection is not associated with phenotypical frailty in older patients, a prospective cohort study.
Article Snippet: The primary predictor was influenza infection as diagnosed by PCR (Simplexa Flu A/B and RSV Direct; DiaSorin Molecular).

Article Title: Comparison of the Panther Fusion respiratory panels to routine methods for detection of viruses in upper and lower respiratory tract specimens.
Article Snippet: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record.. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article.. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Article Title: Influenza A subtype H3N2 is associated with an increased risk of hospital dissemination - an observational study over six influenza seasons.
Article Snippet: Influenza A and B virus was detected with RT-PCR (Simplexa Flu A/B and RSV direct kit (DiaSorin Molecular LLC, CA, USA) performed on nasopharyngeal swab samples [25].

Article Title: Clinical Impact of Rapid Point-of-Care PCR Influenza Testing in an Urgent Care Setting: a Single-Center Study
Article Snippet: Negative specimens were further evaluated by batched reflex confirmatory testing by PCR using the Simplexa Flu A/B RSV assay (Diasorin Molecular LLC, Cypress, CA) performed at our centralized clinical laboratory.

Article Title: Summarizing Study Characteristics and Diagnostic Performance of Commercially Available Tests for Respiratory Syncytial Virus: A Scoping Literature Review in the COVID-19 Era
Article Snippet: Simplexa Flu A/B & RSV , Diasorin Molecular , Molecular , 60 , Nasopharyngeal swab , Not specified , 73.3 (44.8–91.0) to 87.0 (74.5–94.2) , 99.4 (96.3–99.9) to 100 (98.9–100) , 3 , ( , , ) .

Article Title: Comparative Evaluation of cobas Influenza A/B & RSV and Simplexa Flu A/B & RSV for Rapid Detection of Influenza and Respiratory Syncytial Viruses
Article Snippet: In this study, we compared the cobas Influenza A/B & RSV (cobas Liat; Roche Diagnostics, Indianapolis, IN) with the Simplexa Flu A/B & RSV (Simplexa; Diasorin Molecular, Cypress, CA), and evaluated their performance against the routine RT-PCR method.

Cell Culture:

Article Title: Portable molecular diagnostic instruments in microbiology: current status.
Article Snippet: Manufacturers of the assays reviewed: cobas Liat Influenza A&B assay, cobas Liat Influenza A/B&RSV assay, cobas Cdiff assay and cobas Strep A test (Roche Molecular Diagnostics, Pleasanton, CA, USA); Xpert Xpress Flu/RSV assay (Cepheid, Sunnyvale, CA, USA); FTD Respiratory pathogens 21 panel (FastTrack Diagnostics, Siema, Malta); Alere i Influenza A&B assay or ID Now (Abbott Molecular, Des Plaines, IL, USA); Influenza A/B R-GENE and BioFire Film Array respiratory panel (bioM erieux, Marcy-l’ Etoile, France); xTAG Respiratory Pathogen Panel and Aries Flu A/B&RSV assay (Luminex, Austin, TX, USA), GenMark Dx respiratory viral panel and ePlex-RPP (GenMark Diagnostics, Carlsbad, CA, USA), Simplexa Flu A&B/RSV assay (DiaSorin Molecular, Cypress, CA, USA), Panther Fusion Flu A/B&RSV assay and Prodesse ProFluþ assay (Hologic, Marlborough, MA, USA), R-Dia Flu Influenza A and B assay (Diagenode, Li ege, Belgium) and Quick Vue RADT (Quidel, San Diego, CA, USA). require manual calibration or service and provides an interpreted result in less than 90 minutes.

Article Title: Retrospective observational study of the influence of the COVID-19 outbreak on infants’ hospitalisation for acute bronchiolitis
Article Snippet: The clinical data collected at the time of the bronchiolitis episode included date, age, weight, results of the PCR in nasopharyngeal swabs or aspirates for virus identification (Allplex Respiratory Panel Assays (Seegene), and/or Simplexa Flu A/B & RSV Direct Gen II Kit (Diasorin Molecular)), and medical evolution with duration of the hospitalisation, hopitalisation in ICU, respiratory support (oxygen therapy, high-flow nasal cannula oxygen therapy, non-invasive ventilation, invasive ventilation, and extracorporeal membrane oxygenation, and nutritional support.

Article Title: Influenza infection is not associated with phenotypical frailty in older patients, a prospective cohort study.
Article Snippet: The primary predictor was influenza infection as diagnosed by PCR (Simplexa Flu A/B and RSV Direct; DiaSorin Molecular).

Article Title: Comparison of the Panther Fusion respiratory panels to routine methods for detection of viruses in upper and lower respiratory tract specimens.
Article Snippet: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record.. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article.. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Article Title: Influenza A subtype H3N2 is associated with an increased risk of hospital dissemination - an observational study over six influenza seasons.
Article Snippet: Influenza A and B virus was detected with RT-PCR (Simplexa Flu A/B and RSV direct kit (DiaSorin Molecular LLC, CA, USA) performed on nasopharyngeal swab samples [25].

Article Title: Clinical Impact of Rapid Point-of-Care PCR Influenza Testing in an Urgent Care Setting: a Single-Center Study
Article Snippet: Negative specimens were further evaluated by batched reflex confirmatory testing by PCR using the Simplexa Flu A/B RSV assay (Diasorin Molecular LLC, Cypress, CA) performed at our centralized clinical laboratory.

Article Title: Summarizing Study Characteristics and Diagnostic Performance of Commercially Available Tests for Respiratory Syncytial Virus: A Scoping Literature Review in the COVID-19 Era
Article Snippet: Simplexa Flu A/B & RSV , Diasorin Molecular , Molecular , 60 , Nasopharyngeal swab , Not specified , 73.3 (44.8–91.0) to 87.0 (74.5–94.2) , 99.4 (96.3–99.9) to 100 (98.9–100) , 3 , ( , , ) .

Article Title: Comparative Evaluation of cobas Influenza A/B & RSV and Simplexa Flu A/B & RSV for Rapid Detection of Influenza and Respiratory Syncytial Viruses
Article Snippet: In this study, we compared the cobas Influenza A/B & RSV (cobas Liat; Roche Diagnostics, Indianapolis, IN) with the Simplexa Flu A/B & RSV (Simplexa; Diasorin Molecular, Cypress, CA), and evaluated their performance against the routine RT-PCR method.



Similar Products

98
DiaSorin Biotechnology simplexa flu a b rsv direct gen ii
Simplexa Flu A B Rsv Direct Gen Ii, supplied by DiaSorin Biotechnology, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simplexa+flu/Simplexa+COVID-19+Direct/pm41344482-49-55-63
Average 98 stars, based on 1 article reviews
simplexa flu a b rsv direct gen ii - by Bioz Stars, 2026-10
98/100 stars
  Buy from Supplier

90
DiaSorin Molecular simplexa flu a/b and rsv direct assay
Simplexa Flu A/B And Rsv Direct Assay, supplied by DiaSorin Molecular, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simplexa+flu/simplexa+flu+a+b+and+rsv+direct+assay/pmc09860520__jamanetwopen___e2250634___s001-45-13-16
Average 90 stars, based on 1 article reviews
simplexa flu a/b and rsv direct assay - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

86
DiaSorin Biotechnology simplexa flu a b rsv kit
Simplexa Flu A B Rsv Kit, supplied by DiaSorin Biotechnology, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simplexa+flu/pm37640989-43-13-19
Average 86 stars, based on 1 article reviews
simplexa flu a b rsv kit - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
DiaSorin Molecular rt-pcr simplexa flu a/b and rsv direct kit
Rt Pcr Simplexa Flu A/B And Rsv Direct Kit, supplied by DiaSorin Molecular, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simplexa+flu/simplexa+flu+a+b+and+rsv+direct+assay/pm37419188-43-8-16
Average 90 stars, based on 1 article reviews
rt-pcr simplexa flu a/b and rsv direct kit - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
DiaSorin Molecular simplexa covid-19 direct flu a/b & rsv direct
Epidemic curve of RSV, influenza and SARS CoV-2 infections from hospitalized children in Colorado from October 1, 2021 to April 30, 2022. Legend: Line graphs represent number of cases by week. Black line represents RSV, medium grey line represents influenza, light grey line represents <t>COVID-19.</t>
Simplexa Covid 19 Direct Flu A/B & Rsv Direct, supplied by DiaSorin Molecular, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simplexa+flu/simplexa+flu+a+b+and+rsv+direct+assay/pmc10186845-166-19-28
Average 90 stars, based on 1 article reviews
simplexa covid-19 direct flu a/b & rsv direct - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
DiaSorin Molecular simplexa flu a/b and rsv direct
Epidemic curve of RSV, influenza and SARS CoV-2 infections from hospitalized children in Colorado from October 1, 2021 to April 30, 2022. Legend: Line graphs represent number of cases by week. Black line represents RSV, medium grey line represents influenza, light grey line represents <t>COVID-19.</t>
Simplexa Flu A/B And Rsv Direct, supplied by DiaSorin Molecular, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simplexa+flu/simplexa+flu+a+b+and+rsv+direct+assay/pm35989948-83-9-16
Average 90 stars, based on 1 article reviews
simplexa flu a/b and rsv direct - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
DiaSorin Molecular simplexa flu a/b & rsv
Published sensitivity and specificity of <t> RSV </t> tests reviewed under CLIA guidance only.
Simplexa Flu A/B & Rsv, supplied by DiaSorin Molecular, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simplexa+flu/simplexa+flu+a+b+and+rsv+direct+assay/pmc09384538-96-0-6
Average 90 stars, based on 1 article reviews
simplexa flu a/b & rsv - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
DiaSorin Molecular simplexa flu/rsv duplex
Published sensitivity and specificity of <t> RSV </t> tests reviewed under CLIA guidance only.
Simplexa Flu/Rsv Duplex, supplied by DiaSorin Molecular, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simplexa+flu/simplexa+flu+a+b+and+rsv+direct+assay/pm34244735-48-43-52
Average 90 stars, based on 1 article reviews
simplexa flu/rsv duplex - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Epidemic curve of RSV, influenza and SARS CoV-2 infections from hospitalized children in Colorado from October 1, 2021 to April 30, 2022. Legend: Line graphs represent number of cases by week. Black line represents RSV, medium grey line represents influenza, light grey line represents COVID-19.

Journal: The Journal of Pediatrics

Article Title: RSV, Influenza, and COVID-19 Hospitalizations in Children in Colorado During the 2021-2022 Respiratory Virus Season

doi: 10.1016/j.jpeds.2023.113491

Figure Lengend Snippet: Epidemic curve of RSV, influenza and SARS CoV-2 infections from hospitalized children in Colorado from October 1, 2021 to April 30, 2022. Legend: Line graphs represent number of cases by week. Black line represents RSV, medium grey line represents influenza, light grey line represents COVID-19.

Article Snippet: PCR testing was conducted at the CHCO microbiology laboratory using the GeneXpert Xpress CoV-2/Flu/RSV (Cepheid, Sunnyvale, CA) or the Simplexa COVID-19 Direct and Flu A/B & RSV Direct (Diasorin Molecular, Cypress, CA); additional SARS-CoV-2 testing was conducted with the Abbott m2000 Real time assay.

Techniques:

Published sensitivity and specificity of  RSV  tests reviewed under CLIA guidance only.

Journal: The Journal of Applied Laboratory Medicine

Article Title: Summarizing Study Characteristics and Diagnostic Performance of Commercially Available Tests for Respiratory Syncytial Virus: A Scoping Literature Review in the COVID-19 Era

doi: 10.1093/jalm/jfac058

Figure Lengend Snippet: Published sensitivity and specificity of RSV tests reviewed under CLIA guidance only.

Article Snippet: Simplexa Flu A/B & RSV , Diasorin Molecular , Molecular , 60 , Nasopharyngeal swab , Not specified , 73.3 (44.8–91.0) to 87.0 (74.5–94.2) , 99.4 (96.3–99.9) to 100 (98.9–100) , 3 , ( , , ) .

Techniques: Surround Optical-fiber Immunoassay, Luminex